+/* MBC state machine switches into charging mode when the battery voltage
+ * falls below 96% of a battery float voltage. But the voltage drop in Li-ion
+ * batteries is marginal(1~2 %) till about 80% of its capacity - which means,
+ * after a BATFULL, charging won't be restarted until 80%.
+ *
+ * This work_struct function restarts charging at regular intervals to make
+ * sure we don't discharge too much
+ */
+
+static void pcf50633_mbc_charging_restart(struct work_struct *work)
+{
+ struct pcf50633_mbc *mbc;
+ u8 mbcs2, chgmod;
+
+ mbc = container_of(work, struct pcf50633_mbc,
+ charging_restart_work.work);
+
+ mbcs2 = pcf50633_reg_read(mbc->pcf, PCF50633_REG_MBCS2);
+ chgmod = (mbcs2 & PCF50633_MBCS2_MBC_MASK);
+
+ if (chgmod != PCF50633_MBCS2_MBC_BAT_FULL)
+ return;
+
+ /* Restart charging */
+ pcf50633_reg_set_bit_mask(mbc->pcf, PCF50633_REG_MBCC1,
+ PCF50633_MBCC1_RESUME, PCF50633_MBCC1_RESUME);
+ mbc->usb_active = 1;
+ power_supply_changed(&mbc->usb);
+
+ dev_info(mbc->pcf->dev, "Charging restarted\n");
+}
+