.enable = rpm_reg_enable,
.disable = rpm_reg_disable,
.is_enabled = rpm_reg_is_enabled,
+ .list_voltage = regulator_list_voltage_linear_range,
+
+ .get_voltage = rpm_reg_get_voltage,
+ .set_voltage = rpm_reg_set_voltage,
+
+ .set_load = rpm_reg_set_load,
+};
+
+static const struct regulator_ops rpm_smps_ldo_ops_fixed = {
+ .enable = rpm_reg_enable,
+ .disable = rpm_reg_disable,
+ .is_enabled = rpm_reg_is_enabled,
+ .list_voltage = regulator_list_voltage_linear_range,
.get_voltage = rpm_reg_get_voltage,
.set_voltage = rpm_reg_set_voltage,
static const struct regulator_desc pm8941_lnldo = {
.fixed_uV = 1740000,
.n_voltages = 1,
- .ops = &rpm_smps_ldo_ops,
+ .ops = &rpm_smps_ldo_ops_fixed,
};
static const struct regulator_desc pm8941_switch = {