mfd: ab8500-sysctrl: Only reboot into charging mode if battery type is known
authorJonas Aaberg <jonas.aberg@stericsson.com>
Wed, 17 Aug 2011 13:58:52 +0000 (15:58 +0200)
committerLee Jones <lee.jones@linaro.org>
Mon, 4 Feb 2013 08:28:44 +0000 (08:28 +0000)
When a charger is connected, we usually want AB8500 based systems to
reboot into charging-only mode. However, if the battery type cannot
be identified this would be futile, so we'll just shut the system
down instead.

Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Jonas Aaberg <jonas.aberg@stericsson.com>
Reviewed-by: Karl KOMIEROWSKI <karl.komierowski@stericsson.com>
drivers/mfd/ab8500-sysctrl.c

index 188d22b..405ca68 100644 (file)
@@ -23,6 +23,10 @@ void ab8500_power_off(void)
        sigset_t all;
        static char *pss[] = {"ab8500_ac", "ab8500_usb"};
        int i;
+       bool charger_present = false;
+       union power_supply_propval val;
+       struct power_supply *psy;
+       int ret;
 
        /*
         * If we have a charger connected and we're powering off,
@@ -30,23 +34,36 @@ void ab8500_power_off(void)
         */
 
        for (i = 0; i < ARRAY_SIZE(pss); i++) {
-               union power_supply_propval val;
-               struct power_supply *psy;
-               int ret;
-
                psy = power_supply_get_by_name(pss[i]);
                if (!psy)
                        continue;
+
                ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val);
 
                if (!ret && val.intval) {
+                       charger_present = true;
+                       break;
+               }
+       }
+
+       if (!charger_present)
+               goto shutdown;
+
+       /* Check if battery is known */
+       psy = power_supply_get_by_name("ab8500_btemp");
+       if (psy) {
+               ret = psy->get_property(psy, POWER_SUPPLY_PROP_TECHNOLOGY,
+                                       &val);
+               if (!ret && val.intval != POWER_SUPPLY_TECHNOLOGY_UNKNOWN) {
                        printk(KERN_INFO
-                              "Charger \"%s\" is connected. Rebooting.\n",
+                              "Charger \"%s\" is connected with known battery."
+                              " Rebooting.\n",
                               pss[i]);
                        machine_restart(NULL);
                }
        }
 
+shutdown:
        sigfillset(&all);
 
        if (!sigprocmask(SIG_BLOCK, &all, &old)) {