EDAC, Documentation: Update X-Gene EDAC binding for L3/SoC subnodes
authorLoc Ho <lho@apm.com>
Thu, 24 Sep 2015 00:40:58 +0000 (17:40 -0700)
committerBorislav Petkov <bp@suse.de>
Fri, 25 Sep 2015 12:13:41 +0000 (14:13 +0200)
Update documentation for the APM X-Gene SoC EDAC DTS binding for L3/SoC
subnodes.

Signed-off-by: Loc Ho <lho@apm.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Cc: devicetree@vger.kernel.org
Cc: Ian Campbell <ijc+devicetree@hellion.org.uk>
Cc: jcm@redhat.com
Cc: Kumar Gala <galak@codeaurora.org>
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-edac <linux-edac@vger.kernel.org>
Cc: Mark Rutland <mark.rutland@arm.com>
Cc: mchehab@osg.samsung.com
Cc: patches@apm.com
Cc: Pawel Moll <pawel.moll@arm.com>
Cc: Rob Herring <robh+dt@kernel.org>
Link: http://lkml.kernel.org/r/1443055261-8613-2-git-send-email-lho@apm.com
Signed-off-by: Borislav Petkov <bp@suse.de>
Documentation/devicetree/bindings/edac/apm-xgene-edac.txt

index 78edb80..78e2a31 100644 (file)
@@ -5,6 +5,8 @@ The follow error types are supported:
 
   memory controller    - Memory controller
   PMD (L1/L2)          - Processor module unit (PMD) L1/L2 cache
+  L3                   - L3 cache controller
+  SoC                  - SoC IP's such as Ethernet, SATA, and etc
 
 The following section describes the EDAC DT node binding.
 
@@ -30,6 +32,17 @@ Required properties for PMD subnode:
 - reg                  : First resource shall be the PMD resource.
 - pmd-controller       : Instance number of the PMD controller.
 
+Required properties for L3 subnode:
+- compatible           : Shall be "apm,xgene-edac-l3" or
+                          "apm,xgene-edac-l3-v2".
+- reg                  : First resource shall be the L3 EDAC resource.
+
+Required properties for SoC subnode:
+- compatible           : Shall be "apm,xgene-edac-soc-v1" for revision 1 or
+                          "apm,xgene-edac-l3-soc" for general value reporting
+                          only.
+- reg                  : First resource shall be the SoC EDAC resource.
+
 Example:
        csw: csw@7e200000 {
                compatible = "apm,xgene-csw", "syscon";
@@ -76,4 +89,14 @@ Example:
                        reg = <0x0 0x7c000000 0x0 0x200000>;
                        pmd-controller = <0>;
                };
+
+               edacl3@7e600000 {
+                       compatible = "apm,xgene-edac-l3";
+                       reg = <0x0 0x7e600000 0x0 0x1000>;
+               };
+
+               edacsoc@7e930000 {
+                       compatible = "apm,xgene-edac-soc-v1";
+                       reg = <0x0 0x7e930000 0x0 0x1000>;
+               };
        };