From 3cf265662c4b3902787d5d1235140a942d7ffa5a Mon Sep 17 00:00:00 2001 From: Alexandre Belloni Date: Tue, 12 Jul 2016 22:07:59 +0200 Subject: [PATCH] Documentation: dt: iio: at91_adc: fix trigger node names The trigger doesn't need the reg property. When it is not defined, the node name doesn't need a unit-address. Remove them from the example. Signed-off-by: Alexandre Belloni --- .../devicetree/bindings/iio/adc/at91_adc.txt | 12 ++++-------- 1 file changed, 4 insertions(+), 8 deletions(-) diff --git a/Documentation/devicetree/bindings/iio/adc/at91_adc.txt b/Documentation/devicetree/bindings/iio/adc/at91_adc.txt index 0f813dec5e08..f65b04fb7962 100644 --- a/Documentation/devicetree/bindings/iio/adc/at91_adc.txt +++ b/Documentation/devicetree/bindings/iio/adc/at91_adc.txt @@ -59,28 +59,24 @@ adc0: adc@fffb0000 { atmel,adc-res-names = "lowres", "highres"; atmel,adc-use-res = "lowres"; - trigger@0 { - reg = <0>; + trigger0 { trigger-name = "external-rising"; trigger-value = <0x1>; trigger-external; }; - trigger@1 { - reg = <1>; + trigger1 { trigger-name = "external-falling"; trigger-value = <0x2>; trigger-external; }; - trigger@2 { - reg = <2>; + trigger2 { trigger-name = "external-any"; trigger-value = <0x3>; trigger-external; }; - trigger@3 { - reg = <3>; + trigger3 { trigger-name = "continuous"; trigger-value = <0x6>; }; -- 2.20.1