dpif-netlink: add GENEVE creation support
[cascardo/ovs.git] / INSTALL.DPDK.md
index 1287fea..00e75bd 100644 (file)
@@ -16,7 +16,7 @@ OVS needs a system with 1GB hugepages support.
 Building and Installing:
 ------------------------
 
-Required: DPDK 2.0
+Required: DPDK 16.04, libnuma
 Optional (if building with vhost-cuse): `fuse`, `fuse-devel` (`libfuse-dev`
 on Debian/Ubuntu)
 
@@ -24,28 +24,18 @@ on Debian/Ubuntu)
   1. Set `$DPDK_DIR`
 
      ```
-     export DPDK_DIR=/usr/src/dpdk-2.0
+     export DPDK_DIR=/usr/src/dpdk-16.04
      cd $DPDK_DIR
      ```
 
-  2. Update `config/common_linuxapp` so that DPDK generate single lib file.
-     (modification also required for IVSHMEM build)
-
-     `CONFIG_RTE_BUILD_COMBINE_LIBS=y`
-
-     Update `config/common_linuxapp` so that DPDK is built with vhost
-     libraries.
-
-     `CONFIG_RTE_LIBRTE_VHOST=y`
-
-     Then run `make install` to build and install the library.
+  2. Then run `make install` to build and install the library.
      For default install without IVSHMEM:
 
-     `make install T=x86_64-native-linuxapp-gcc`
+     `make install T=x86_64-native-linuxapp-gcc DESTDIR=install`
 
      To include IVSHMEM (shared memory):
 
-     `make install T=x86_64-ivshmem-linuxapp-gcc`
+     `make install T=x86_64-ivshmem-linuxapp-gcc DESTDIR=install`
 
      For further details refer to http://dpdk.org/
 
@@ -65,7 +55,7 @@ on Debian/Ubuntu)
      `export DPDK_BUILD=$DPDK_DIR/x86_64-ivshmem-linuxapp-gcc/`
 
    ```
-   cd $(OVS_DIR)/openvswitch
+   cd $(OVS_DIR)/
    ./boot.sh
    ./configure --with-dpdk=$DPDK_BUILD [CFLAGS="-g -O2 -Wno-cast-align"]
    make
@@ -112,7 +102,7 @@ Using the DPDK with ovs-vswitchd:
      3. Bind network device to vfio-pci:
         `$DPDK_DIR/tools/dpdk_nic_bind.py --bind=vfio-pci eth1`
 
-3. Mount the hugetable filsystem
+3. Mount the hugetable filesystem
 
    `mount -t hugetlbfs -o pagesize=1G none /dev/hugepages`
 
@@ -148,22 +138,67 @@ Using the DPDK with ovs-vswitchd:
 
 5. Start vswitchd:
 
-   DPDK configuration arguments can be passed to vswitchd via `--dpdk`
-   argument. This needs to be first argument passed to vswitchd process.
-   dpdk arg -c is ignored by ovs-dpdk, but it is a required parameter
-   for dpdk initialization.
+   DPDK configuration arguments can be passed to vswitchd via Open_vSwitch
+   other_config column. The recognized configuration options are listed.
+   Defaults will be provided for all values not explicitly set.
+
+   * dpdk-init
+   Specifies whether OVS should initialize and support DPDK ports. This is
+   a boolean, and defaults to false.
+
+   * dpdk-lcore-mask
+   Specifies the CPU cores on which dpdk lcore threads should be spawned.
+   The DPDK lcore threads are used for DPDK library tasks, such as
+   library internal message processing, logging, etc. Value should be in
+   the form of a hex string (so '0x123') similar to the 'taskset' mask
+   input.
+   If not specified, the value will be determined by choosing the lowest
+   CPU core from initial cpu affinity list. Otherwise, the value will be
+   passed directly to the DPDK library.
+   For performance reasons, it is best to set this to a single core on
+   the system, rather than allow lcore threads to float.
+
+   * dpdk-alloc-mem
+   This sets the total memory to preallocate from hugepages regardless of
+   processor socket. It is recommended to use dpdk-socket-mem instead.
+
+   * dpdk-socket-mem
+   Comma separated list of memory to pre-allocate from hugepages on specific
+   sockets.
+
+   * dpdk-hugepage-dir
+   Directory where hugetlbfs is mounted
+
+   * dpdk-extra
+   Extra arguments to provide to DPDK EAL, as previously specified on the
+   command line. Do not pass '--no-huge' to the system in this way. Support
+   for running the system without hugepages is nonexistent.
+
+   * cuse-dev-name
+   Option to set the vhost_cuse character device name.
+
+   * vhost-sock-dir
+   Option to set the path to the vhost_user unix socket files.
+
+   NOTE: Changing any of these options requires restarting the ovs-vswitchd
+   application.
+
+   Open vSwitch can be started as normal. DPDK will be initialized as long
+   as the dpdk-init option has been set to 'true'.
+
 
    ```
    export DB_SOCK=/usr/local/var/run/openvswitch/db.sock
-   ovs-vswitchd --dpdk -c 0x1 -n 4 -- unix:$DB_SOCK --pidfile --detach
+   ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-init=true
+   ovs-vswitchd unix:$DB_SOCK --pidfile --detach
    ```
 
    If allocated more than one GB hugepage (as for IVSHMEM), set amount and
    use NUMA node 0 memory:
 
    ```
-   ovs-vswitchd --dpdk -c 0x1 -n 4 --socket-mem 1024,0 \
-   -- unix:$DB_SOCK --pidfile --detach
+   ovs-vsctl --no-wait set Open_vSwitch . other_config:dpdk-socket-mem="1024,0"
+   ovs-vswitchd unix:$DB_SOCK --pidfile --detach
    ```
 
 6. Add bridge & ports
@@ -173,9 +208,9 @@ Using the DPDK with ovs-vswitchd:
 
    `ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev`
 
-   Now you can add dpdk devices. OVS expect DPDK device name start with dpdk
-   and end with portid. vswitchd should print (in the log file) the number
-   of dpdk devices found.
+   Now you can add dpdk devices. OVS expects DPDK device names to start with
+   "dpdk" and end with a portid. vswitchd should print (in the log file) the
+   number of dpdk devices found.
 
    ```
    ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
@@ -212,61 +247,274 @@ Using the DPDK with ovs-vswitchd:
    ./ovs-ofctl add-flow br0 in_port=2,action=output:1
    ```
 
-8. Performance tuning
+8. QoS usage example
+
+   Assuming you have a vhost-user port transmitting traffic consisting of
+   packets of size 64 bytes, the following command would limit the egress
+   transmission rate of the port to ~1,000,000 packets per second:
+
+   `ovs-vsctl set port vhost-user0 qos=@newqos -- --id=@newqos create qos
+   type=egress-policer other-config:cir=46000000 other-config:cbs=2048`
+
+   To examine the QoS configuration of the port:
+
+   `ovs-appctl -t ovs-vswitchd qos/show vhost-user0`
+
+   To clear the QoS configuration from the port and ovsdb use the following:
+
+   `ovs-vsctl destroy QoS vhost-user0 -- clear Port vhost-user0 qos`
+
+   For more details regarding egress-policer parameters please refer to the
+   vswitch.xml.
+
+9. Ingress Policing Example
 
-   With pmd multi-threading support, OVS creates one pmd thread for each
-   numa node as default.  The pmd thread handles the I/O of all DPDK
-   interfaces on the same numa node.  The following two commands can be used
-   to configure the multi-threading behavior.
+   Assuming you have a vhost-user port receiving traffic consisting of
+   packets of size 64 bytes, the following command would limit the reception
+   rate of the port to ~1,000,000 packets per second:
+
+   `ovs-vsctl set interface vhost-user0 ingress_policing_rate=368000
+    ingress_policing_burst=1000`
+
+   To examine the ingress policer configuration of the port:
+
+   `ovs-vsctl list interface vhost-user0`
+
+   To clear the ingress policer configuration from the port use the following:
+
+   `ovs-vsctl set interface vhost-user0 ingress_policing_rate=0`
+
+   For more details regarding ingress-policer see the vswitch.xml.
+
+Performance Tuning:
+-------------------
+
+1. PMD affinitization
+
+   A poll mode driver (pmd) thread handles the I/O of all DPDK
+   interfaces assigned to it. A pmd thread will busy loop through
+   the assigned port/rxq's polling for packets, switch the packets
+   and send to a tx port if required. Typically, it is found that
+   a pmd thread is CPU bound, meaning that the greater the CPU
+   occupancy the pmd thread can get, the better the performance. To
+   that end, it is good practice to ensure that a pmd thread has as
+   many cycles on a core available to it as possible. This can be
+   achieved by affinitizing the pmd thread with a core that has no
+   other workload. See section 7 below for a description of how to
+   isolate cores for this purpose also.
+
+   The following command can be used to specify the affinity of the
+   pmd thread(s).
 
    `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>`
 
-   The command above asks for a CPU mask for setting the affinity of pmd
-   threads.  A set bit in the mask means a pmd thread is created and pinned
-   to the corresponding CPU core.  For more information, please refer to
+   By setting a bit in the mask, a pmd thread is created and pinned
+   to the corresponding CPU core. e.g. to run a pmd thread on core 1
+
+   `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=2`
+
+   For more information, please refer to the Open_vSwitch TABLE section in
+
    `man ovs-vswitchd.conf.db`
 
-   `ovs-vsctl set Open_vSwitch . other_config:n-dpdk-rxqs=<integer>`
+   Note, that a pmd thread on a NUMA node is only created if there is
+   at least one DPDK interface from that NUMA node added to OVS.
+
+2. Multiple poll mode driver threads
+
+   With pmd multi-threading support, OVS creates one pmd thread
+   for each NUMA node by default. However, it can be seen that in cases
+   where there are multiple ports/rxq's producing traffic, performance
+   can be improved by creating multiple pmd threads running on separate
+   cores. These pmd threads can then share the workload by each being
+   responsible for different ports/rxq's. Assignment of ports/rxq's to
+   pmd threads is done automatically.
 
-   The command above sets the number of rx queues of each DPDK interface. The
-   rx queues are assigned to pmd threads on the same numa node in round-robin
-   fashion.  For more information, please refer to `man ovs-vswitchd.conf.db`
+   The following command can be used to specify the affinity of the
+   pmd threads.
 
-   Ideally for maximum throughput, the pmd thread should not be scheduled out
-   which temporarily halts its execution. The following affinitization methods
-   can help.
+   `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>`
+
+   A set bit in the mask means a pmd thread is created and pinned
+   to the corresponding CPU core. e.g. to run pmd threads on core 1 and 2
 
-   Lets pick core 4,6,8,10 for pmd threads to run on.  Also assume a dual 8 core
-   sandy bridge system with hyperthreading enabled where CPU1 has cores 0,...,7
-   and 16,...,23 & CPU2 cores 8,...,15 & 24,...,31.  (A different cpu
-   configuration could have different core mask requirements).
+   `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=6`
 
-   To kernel bootline add core isolation list for cores and associated hype cores
-   (e.g.  isolcpus=4,20,6,22,8,24,10,26,).  Reboot system for isolation to take
-   effect, restart everything.
+   For more information, please refer to the Open_vSwitch TABLE section in
 
-   Configure pmd threads on core 4,6,8,10 using 'pmd-cpu-mask':
+   `man ovs-vswitchd.conf.db`
 
-   `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=00000550`
+   For example, when using dpdk and dpdkvhostuser ports in a bi-directional
+   VM loopback as shown below, spreading the workload over 2 or 4 pmd
+   threads shows significant improvements as there will be more total CPU
+   occupancy available.
 
-   You should be able to check that pmd threads are pinned to the correct cores
-   via:
+   NIC port0 <-> OVS <-> VM <-> OVS <-> NIC port 1
+
+   The following command can be used to confirm that the port/rxq assignment
+   to pmd threads is as required:
+
+   `ovs-appctl dpif-netdev/pmd-rxq-show`
+
+   This can also be checked with:
 
    ```
-   top -p `pidof ovs-vswitchd` -H -d1
+   top -H
+   taskset -p <pid_of_pmd>
    ```
 
-   Note, the pmd threads on a numa node are only created if there is at least
-   one DPDK interface from the numa node that has been added to OVS.
-
-   To understand where most of the time is spent and whether the caches are
-   effective, these commands can be used:
+   To understand where most of the pmd thread time is spent and whether the
+   caches are being utilized, these commands can be used:
 
    ```
-   ovs-appctl dpif-netdev/pmd-stats-clear #To reset statistics
+   # Clear previous stats
+   ovs-appctl dpif-netdev/pmd-stats-clear
+
+   # Check current stats
    ovs-appctl dpif-netdev/pmd-stats-show
    ```
 
+3. DPDK port Rx Queues
+
+   `ovs-vsctl set Interface <DPDK interface> options:n_rxq=<integer>`
+
+   The command above sets the number of rx queues for DPDK interface.
+   The rx queues are assigned to pmd threads on the same NUMA node in a
+   round-robin fashion.  For more information, please refer to the
+   Open_vSwitch TABLE section in
+
+   `man ovs-vswitchd.conf.db`
+
+4. Exact Match Cache
+
+   Each pmd thread contains one EMC. After initial flow setup in the
+   datapath, the EMC contains a single table and provides the lowest level
+   (fastest) switching for DPDK ports. If there is a miss in the EMC then
+   the next level where switching will occur is the datapath classifier.
+   Missing in the EMC and looking up in the datapath classifier incurs a
+   significant performance penalty. If lookup misses occur in the EMC
+   because it is too small to handle the number of flows, its size can
+   be increased. The EMC size can be modified by editing the define
+   EM_FLOW_HASH_SHIFT in lib/dpif-netdev.c.
+
+   As mentioned above an EMC is per pmd thread. So an alternative way of
+   increasing the aggregate amount of possible flow entries in EMC and
+   avoiding datapath classifier lookups is to have multiple pmd threads
+   running. This can be done as described in section 2.
+
+5. Compiler options
+
+   The default compiler optimization level is '-O2'. Changing this to
+   more aggressive compiler optimizations such as '-O3' or
+   '-Ofast -march=native' with gcc can produce performance gains.
+
+6. Simultaneous Multithreading (SMT)
+
+   With SMT enabled, one physical core appears as two logical cores
+   which can improve performance.
+
+   SMT can be utilized to add additional pmd threads without consuming
+   additional physical cores. Additional pmd threads may be added in the
+   same manner as described in section 2. If trying to minimize the use
+   of physical cores for pmd threads, care must be taken to set the
+   correct bits in the pmd-cpu-mask to ensure that the pmd threads are
+   pinned to SMT siblings.
+
+   For example, when using 2x 10 core processors in a dual socket system
+   with HT enabled, /proc/cpuinfo will report 40 logical cores. To use
+   two logical cores which share the same physical core for pmd threads,
+   the following command can be used to identify a pair of logical cores.
+
+   `cat /sys/devices/system/cpu/cpuN/topology/thread_siblings_list`
+
+   where N is the logical core number. In this example, it would show that
+   cores 1 and 21 share the same physical core. The pmd-cpu-mask to enable
+   two pmd threads running on these two logical cores (one physical core)
+   is.
+
+   `ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=100002`
+
+   Note that SMT is enabled by the Hyper-Threading section in the
+   BIOS, and as such will apply to the whole system. So the impact of
+   enabling/disabling it for the whole system should be considered
+   e.g. If workloads on the system can scale across multiple cores,
+   SMT may very beneficial. However, if they do not and perform best
+   on a single physical core, SMT may not be beneficial.
+
+7. The isolcpus kernel boot parameter
+
+   isolcpus can be used on the kernel bootline to isolate cores from the
+   kernel scheduler and hence dedicate them to OVS or other packet
+   forwarding related workloads. For example a Linux kernel boot-line
+   could be:
+
+   ```
+   GRUB_CMDLINE_LINUX_DEFAULT="quiet hugepagesz=1G hugepages=4
+   default_hugepagesz=1G 'intel_iommu=off' isolcpus=1-19"
+   ```
+
+8. NUMA/Cluster On Die
+
+   Ideally inter NUMA datapaths should be avoided where possible as packets
+   will go across QPI and there may be a slight performance penalty when
+   compared with intra NUMA datapaths. On Intel Xeon Processor E5 v3,
+   Cluster On Die is introduced on models that have 10 cores or more.
+   This makes it possible to logically split a socket into two NUMA regions
+   and again it is preferred where possible to keep critical datapaths
+   within the one cluster.
+
+   It is good practice to ensure that threads that are in the datapath are
+   pinned to cores in the same NUMA area. e.g. pmd threads and QEMU vCPUs
+   responsible for forwarding. If DPDK is built with
+   CONFIG_RTE_LIBRTE_VHOST_NUMA=y, vHost User ports automatically
+   detect the NUMA socket of the QEMU vCPUs and will be serviced by a PMD
+   from the same node provided a core on this node is enabled in the
+   pmd-cpu-mask.
+
+9. Rx Mergeable buffers
+
+   Rx Mergeable buffers is a virtio feature that allows chaining of multiple
+   virtio descriptors to handle large packet sizes. As such, large packets
+   are handled by reserving and chaining multiple free descriptors
+   together. Mergeable buffer support is negotiated between the virtio
+   driver and virtio device and is supported by the DPDK vhost library.
+   This behavior is typically supported and enabled by default, however
+   in the case where the user knows that rx mergeable buffers are not needed
+   i.e. jumbo frames are not needed, it can be forced off by adding
+   mrg_rxbuf=off to the QEMU command line options. By not reserving multiple
+   chains of descriptors it will make more individual virtio descriptors
+   available for rx to the guest using dpdkvhost ports and this can improve
+   performance.
+
+10. Packet processing in the guest
+
+   It is good practice whether simply forwarding packets from one
+   interface to another or more complex packet processing in the guest,
+   to ensure that the thread performing this work has as much CPU
+   occupancy as possible. For example when the DPDK sample application
+   `testpmd` is used to forward packets in the guest, multiple QEMU vCPU
+   threads can be created. Taskset can then be used to affinitize the
+   vCPU thread responsible for forwarding to a dedicated core not used
+   for other general processing on the host system.
+
+11. DPDK virtio pmd in the guest
+
+   dpdkvhostcuse or dpdkvhostuser ports can be used to accelerate the path
+   to the guest using the DPDK vhost library. This library is compatible with
+   virtio-net drivers in the guest but significantly better performance can
+   be observed when using the DPDK virtio pmd driver in the guest. The DPDK
+   `testpmd` application can be used in the guest as an example application
+   that forwards packet from one DPDK vhost port to another. An example of
+   running `testpmd` in the guest can be seen here.
+
+   ```
+   ./testpmd -c 0x3 -n 4 --socket-mem 512 -- --burst=64 -i --txqflags=0xf00
+   --disable-hw-vlan --forward-mode=io --auto-start
+   ```
+
+   See below information on dpdkvhostcuse and dpdkvhostuser ports.
+   See [DPDK Docs] for more information on `testpmd`.
+
 DPDK Rings :
 ------------
 
@@ -315,7 +563,7 @@ the vswitchd.
 DPDK vhost:
 -----------
 
-DPDK 2.0 supports two types of vhost:
+DPDK 16.04 supports two types of vhost:
 
 1. vhost-user
 2. vhost-cuse
@@ -336,7 +584,7 @@ with OVS.
 DPDK vhost-user Prerequisites:
 -------------------------
 
-1. DPDK 2.0 with vhost support enabled as documented in the "Building and
+1. DPDK 16.04 with vhost support enabled as documented in the "Building and
    Installing section"
 
 2. QEMU version v2.1.0+
@@ -350,7 +598,8 @@ Adding DPDK vhost-user ports to the Switch:
 
 Following the steps above to create a bridge, you can now add DPDK vhost-user
 as a port to the vswitch. Unlike DPDK ring ports, DPDK vhost-user ports can
-have arbitrary names.
+have arbitrary names, except that forward and backward slashes are prohibited
+in the names.
 
   -  For vhost-user, the name of the port type is `dpdkvhostuser`
 
@@ -363,11 +612,12 @@ have arbitrary names.
      `/usr/local/var/run/openvswitch/vhost-user-1`, which you must provide
      to your VM on the QEMU command line. More instructions on this can be
      found in the next section "DPDK vhost-user VM configuration"
-     Note: If you wish for the vhost-user sockets to be created in a
-     directory other than `/usr/local/var/run/openvswitch`, you may specify
-     another location on the ovs-vswitchd command line like so:
+  - If you wish for the vhost-user sockets to be created in a sub-directory of
+    `/usr/local/var/run/openvswitch`, you may specify this directory in the
+    ovsdb like so:
 
-      `./vswitchd/ovs-vswitchd --dpdk -vhost_sock_dir /my-dir -c 0x1 ...`
+      `./utilities/ovs-vsctl --no-wait \
+        set Open_vSwitch . other_config:vhost-sock-dir=subdir`
 
 DPDK vhost-user VM configuration:
 ---------------------------------
@@ -409,6 +659,41 @@ Follow the steps below to attach vhost-user port(s) to a VM.
    -numa node,memdev=mem -mem-prealloc
    ```
 
+3. Optional: Enable multiqueue support
+   The vhost-user interface must be configured in Open vSwitch with the
+   desired amount of queues with:
+
+   ```
+   ovs-vsctl set Interface vhost-user-2 options:n_rxq=<requested queues>
+   ```
+
+   QEMU needs to be configured as well.
+   The $q below should match the queues requested in OVS (if $q is more,
+   packets will not be received).
+   The $v is the number of vectors, which is '$q x 2 + 2'.
+
+   ```
+   -chardev socket,id=char2,path=/usr/local/var/run/openvswitch/vhost-user-2
+   -netdev type=vhost-user,id=mynet2,chardev=char2,vhostforce,queues=$q
+   -device virtio-net-pci,mac=00:00:00:00:00:02,netdev=mynet2,mq=on,vectors=$v
+   ```
+
+   If one wishes to use multiple queues for an interface in the guest, the
+   driver in the guest operating system must be configured to do so. It is
+   recommended that the number of queues configured be equal to '$q'.
+
+   For example, this can be done for the Linux kernel virtio-net driver with:
+
+   ```
+   ethtool -L <DEV> combined <$q>
+   ```
+
+   A note on the command above:
+
+   `-L`: Changes the numbers of channels of the specified network device
+
+   `combined`: Changes the number of multi-purpose channels.
+
 DPDK vhost-cuse:
 ----------------
 
@@ -418,10 +703,10 @@ with OVS.
 DPDK vhost-cuse Prerequisites:
 -------------------------
 
-1. DPDK 2.0 with vhost support enabled as documented in the "Building and
+1. DPDK 16.04 with vhost support enabled as documented in the "Building and
    Installing section"
    As an additional step, you must enable vhost-cuse in DPDK by setting the
-   following additional flag in `config/common_linuxapp`:
+   following additional flag in `config/common_base`:
 
    `CONFIG_RTE_LIBRTE_VHOST_USER=n`
 
@@ -480,14 +765,13 @@ DPDK vhost-cuse VM configuration:
 
 1. This step is only needed if using an alternative character device.
 
-   The new character device filename must be specified on the vswitchd
-   commandline:
+   The new character device filename must be specified in the ovsdb:
 
-        `./vswitchd/ovs-vswitchd --dpdk --cuse_dev_name my-vhost-net -c 0x1 ...`
+        `./utilities/ovs-vsctl --no-wait set Open_vSwitch . \
+                          other_config:cuse-dev-name=my-vhost-net`
 
-   Note that the `--cuse_dev_name` argument and associated string must be the first
-   arguments after `--dpdk` and come before the EAL arguments. In the example
-   above, the character device to be used will be `/dev/my-vhost-net`.
+   In the example above, the character device to be used will be
+   `/dev/my-vhost-net`.
 
 2. This step is only needed if reusing the standard character device. It will
    conflict with the kernel vhost character device so the user must first
@@ -529,7 +813,7 @@ DPDK vhost-cuse VM configuration:
        subprocess.call("qemu-system-x86_64 .... -netdev tap,id=vhostnet0,\
                         vhost=on,vhostfd=" + fd +"...", shell=True)
 
-   Alternatively the the `qemu-wrap.py` script can be used to automate the
+   Alternatively the `qemu-wrap.py` script can be used to automate the
    requirements specified above and can be used in conjunction with libvirt if
    desired. See the "DPDK vhost VM configuration with QEMU wrapper" section
    below.
@@ -599,8 +883,8 @@ steps.
         ```
 
         <my-vhost-device> refers to "vhost-net" if using the `/dev/vhost-net`
-        device. If you have specificed a different name on the ovs-vswitchd
-        commandline using the "--cuse_dev_name" parameter, please specify that
+        device. If you have specificed a different name in the database
+        using the "other_config:cuse-dev-name" parameter, please specify that
         filename instead.
 
      2. Disable SELinux or set to permissive mode
@@ -720,6 +1004,19 @@ Restrictions:
     want to share dpdkr rings with other processes on the host, you can do
     this with smaller page sizes.
 
+  Platform and Network Interface:
+  - By default with DPDK 16.04, a maximum of 64 TX queues can be used with an
+    Intel XL710 Network Interface on a platform with more than 64 logical
+    cores. If a user attempts to add an XL710 interface as a DPDK port type to
+    a system as described above, an error will be reported that initialization
+    failed for the 65th queue. OVS will then roll back to the previous
+    successful queue initialization and use that value as the total number of
+    TX queues available with queue locking. If a user wishes to use more than
+    64 queues and avoid locking, then the
+    `CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF` config parameter in DPDK must be
+    increased to the desired number of queues. Both DPDK and OVS must be
+    recompiled for this change to take effect.
+
 Bug Reporting:
 --------------