-/* Populates 'status' with the status of BFD on 'ofport'. Returns 0 on
- * success. Returns a negative number if there is no status change since
- * last update. Returns a positive errno otherwise. Has no effect if
- * 'ofp_port' is not an OpenFlow port in 'ofproto'.
+/* Populates 'status' with the status of BFD on 'ofport'. If 'force' is set to
+ * true, status will be returned even if there is no status change since last
+ * update.
+ *
+ * Returns 0 on success. Returns a negative number if there is no status change
+ * since last update and 'force' is set to false. Returns a positive errno
+ * otherwise. Has no effect if 'ofp_port' is not an OpenFlow port in 'ofproto'.
*
* The caller must provide and own '*status'. */
int
ofproto_port_get_bfd_status(struct ofproto *ofproto, ofp_port_t ofp_port,
- struct smap *status)
+ bool force, struct smap *status)
{
struct ofport *ofport = ofproto_get_port(ofproto, ofp_port);
return (ofport && ofproto->ofproto_class->get_bfd_status
- ? ofproto->ofproto_class->get_bfd_status(ofport, status)
+ ? ofproto->ofproto_class->get_bfd_status(ofport, force, status)
: EOPNOTSUPP);
}
ofproto->ofproto_class->get_netflow_ids(ofproto, engine_type, engine_id);
}
-/* Checks the status of CFM configured on 'ofp_port' within 'ofproto'.
- * Returns 0 if the port's CFM status was successfully stored into
- * '*status'. Returns positive errno if the port did not have CFM
- * configured. Returns negative number if there is no status change
- * since last update.
+/* Checks the status of CFM configured on 'ofp_port' within 'ofproto' and stores
+ * the port's CFM status in '*status'. If 'force' is set to true, status will
+ * be returned even if there is no status change since last update.
+ *
+ * Returns 0 on success. Returns a negative number if there is no status
+ * change since last update and 'force' is set to false. Returns positive errno
+ * if the port did not have CFM configured.
*
* The caller must provide and own '*status', and must free 'status->rmps'.
* '*status' is indeterminate if the return value is non-zero. */
int
ofproto_port_get_cfm_status(const struct ofproto *ofproto, ofp_port_t ofp_port,
- struct ofproto_cfm_status *status)
+ bool force, struct ofproto_cfm_status *status)
{
struct ofport *ofport = ofproto_get_port(ofproto, ofp_port);
return (ofport && ofproto->ofproto_class->get_cfm_status
- ? ofproto->ofproto_class->get_cfm_status(ofport, status)
+ ? ofproto->ofproto_class->get_cfm_status(ofport, force, status)
: EOPNOTSUPP);
}