mmc: sdhci: fix data timeout (part 2)
authorRussell King <rmk+kernel@arm.linux.org.uk>
Tue, 26 Jan 2016 13:41:04 +0000 (13:41 +0000)
committerUlf Hansson <ulf.hansson@linaro.org>
Mon, 29 Feb 2016 10:03:17 +0000 (11:03 +0100)
The calculation for the timeout based on the number of card clocks is
incorrect.  The calculation assumed:

timeout in microseconds = clock cycles / clock in Hz

which is clearly a several orders of magnitude wrong.  Fix this by
multiplying the clock cycles by 1000000 prior to dividing by the Hz
based clock.  Also, as per part 1, ensure that the division rounds
up.

As this needs 64-bit math via do_div(), avoid it if the clock cycles
is zero.

Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Signed-off-by: Adrian Hunter <adrian.hunter@intel.com>
Cc: stable@vger.kernel.org # v3.15+
Tested-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
drivers/mmc/host/sdhci.c

index 1d1b3c5..5a7517f 100644 (file)
@@ -636,8 +636,19 @@ static u8 sdhci_calc_timeout(struct sdhci_host *host, struct mmc_command *cmd)
                target_timeout = cmd->busy_timeout * 1000;
        else {
                target_timeout = DIV_ROUND_UP(data->timeout_ns, 1000);
-               if (host->clock)
-                       target_timeout += data->timeout_clks / host->clock;
+               if (host->clock && data->timeout_clks) {
+                       unsigned long long val;
+
+                       /*
+                        * data->timeout_clks is in units of clock cycles.
+                        * host->clock is in Hz.  target_timeout is in us.
+                        * Hence, us = 1000000 * cycles / Hz.  Round up.
+                        */
+                       val = 1000000 * data->timeout_clks;
+                       if (do_div(val, host->clock))
+                               target_timeout++;
+                       target_timeout += val;
+               }
        }
 
        /*