doc: Add more cross references between docs
[cascardo/ovs.git] / INSTALL.DPDK.md
1 Using Open vSwitch with DPDK
2 ============================
3
4 Open vSwitch can use Intel(R) DPDK lib to operate entirely in
5 userspace. This file explains how to install and use Open vSwitch in
6 such a mode.
7
8 The DPDK support of Open vSwitch is considered experimental.
9 It has not been thoroughly tested.
10
11 This version of Open vSwitch should be built manually with `configure`
12 and `make`.
13
14 OVS needs a system with 1GB hugepages support.
15
16 Building and Installing:
17 ------------------------
18
19 Required DPDK 1.7
20
21 1. Configure build & install DPDK:
22   1. Set `$DPDK_DIR`
23
24      ```
25      export DPDK_DIR=/usr/src/dpdk-1.7.1
26      cd $DPDK_DIR
27      ```
28
29   2. Update `config/common_linuxapp` so that DPDK generate single lib file.
30      (modification also required for IVSHMEM build)
31
32      `CONFIG_RTE_BUILD_COMBINE_LIBS=y`
33
34      Then run `make install` to build and isntall the library.
35      For default install without IVSHMEM:
36
37      `make install T=x86_64-native-linuxapp-gcc`
38
39      To include IVSHMEM (shared memory):
40
41      `make install T=x86_64-ivshmem-linuxapp-gcc`
42
43      For further details refer to http://dpdk.org/
44
45 2. Configure & build the Linux kernel:
46
47    Refer to intel-dpdk-getting-started-guide.pdf for understanding
48    DPDK kernel requirement.
49
50 3. Configure & build OVS:
51
52    * Non IVSHMEM:
53
54      `export DPDK_BUILD=$DPDK_DIR/x86_64-native-linuxapp-gcc/`
55
56    * IVSHMEM:
57
58      `export DPDK_BUILD=$DPDK_DIR/x86_64-ivshmem-linuxapp-gcc/`
59
60    ```
61    cd $(OVS_DIR)/openvswitch
62    ./boot.sh
63    ./configure --with-dpdk=$DPDK_BUILD
64    make
65    ```
66
67 To have better performance one can enable aggressive compiler optimizations and
68 use the special instructions(popcnt, crc32) that may not be available on all
69 machines. Instead of typing `make`, type:
70
71 `make CFLAGS='-O3 -march=native'`
72
73 Refer to [INSTALL.userspace.md] for general requirements of building userspace OVS.
74
75 Using the DPDK with ovs-vswitchd:
76 ---------------------------------
77
78 1. Setup system boot
79    Add the following options to the kernel bootline:
80    
81    `default_hugepagesz=1GB hugepagesz=1G hugepages=1`
82
83 2. Setup DPDK devices:
84    1. insert uio.ko: `modprobe uio`
85    2. insert igb_uio.ko: `insmod $DPDK_BUILD/kmod/igb_uio.ko`
86    3. Bind network device to igb_uio: `$DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio eth1`
87
88 3. Mount the hugetable filsystem
89
90    `mount -t hugetlbfs -o pagesize=1G none /dev/hugepages`
91
92    Ref to http://www.dpdk.org/doc/quick-start for verifying DPDK setup.
93
94 4. Start ovsdb-server as discussed in [INSTALL.md] doc:
95    1. First time only db creation (or clearing):
96
97         ```
98         mkdir -p /usr/local/etc/openvswitch
99         mkdir -p /usr/local/var/run/openvswitch
100         rm /usr/local/etc/openvswitch/conf.db
101         cd $OVS_DIR
102         ./ovsdb/ovsdb-tool create /usr/local/etc/openvswitch/conf.db \
103              ./vswitchd/vswitch.ovsschema
104         ```
105
106     2. start ovsdb-server
107
108         ```
109         cd $OVS_DIR
110         ./ovsdb/ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock \
111           --remote=db:Open_vSwitch,Open_vSwitch,manager_options \
112           --private-key=db:Open_vSwitch,SSL,private_key \
113           --certificate=Open_vSwitch,SSL,certificate \
114           --bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --pidfile --detach
115         ```
116
117     3. First time after db creation, initialize:
118
119         ```
120         cd $OVS_DIR
121         ./utilities/ovs-vsctl --no-wait init
122         ```
123
124 5. Start vswitchd:
125
126    DPDK configuration arguments can be passed to vswitchd via `--dpdk`
127    argument. This needs to be first argument passed to vswitchd process.
128    dpdk arg -c is ignored by ovs-dpdk, but it is a required parameter
129    for dpdk initialization.
130
131         export DB_SOCK=/usr/local/var/run/openvswitch/db.sock
132         ./vswitchd/ovs-vswitchd --dpdk -c 0x1 -n 4 -- unix:$DB_SOCK --pidfile --detach
133
134    If allocated more than one GB hugepage (as for IVSHMEM), set amount and use NUMA
135    node 0 memory:
136
137         ./vswitchd/ovs-vswitchd --dpdk -c 0x1 -n 4 --socket-mem 1024,0 \
138           -- unix:$DB_SOCK --pidfile --detach
139
140 6. Add bridge & ports
141           
142    To use ovs-vswitchd with DPDK, create a bridge with datapath_type
143    "netdev" in the configuration database.  For example:
144
145         `ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev`
146
147    Now you can add dpdk devices. OVS expect DPDK device name start with dpdk
148    and end with portid. vswitchd should print (in the log file) the number of dpdk
149    devices found.
150
151         ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
152         ovs-vsctl add-port br0 dpdk1 -- set Interface dpdk1 type=dpdk
153
154     Once first DPDK port is added to vswitchd, it creates a Polling thread and
155     polls dpdk device in continuous loop. Therefore CPU utilization
156     for that thread is always 100%.
157
158 7. Add test flows
159
160    Test flow script across NICs (assuming ovs in /usr/src/ovs):
161    Execute script:
162
163    ```
164    #! /bin/sh
165    # Move to command directory
166    cd /usr/src/ovs/utilities/
167
168    # Clear current flows
169    ./ovs-ofctl del-flows br0
170
171    # Add flows between port 1 (dpdk0) to port 2 (dpdk1)
172    ./ovs-ofctl add-flow br0 in_port=1,action=output:2
173    ./ovs-ofctl add-flow br0 in_port=2,action=output:1
174    ```
175
176 8. Performance tuning
177
178    With pmd multi-threading support, OVS creates one pmd thread for each
179    numa node as default.  The pmd thread handles the I/O of all DPDK
180    interfaces on the same numa node.  The following two commands can be used
181    to configure the multi-threading behavior.
182
183         ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>
184
185    The command above asks for a CPU mask for setting the affinity of pmd threads.
186    A set bit in the mask means a pmd thread is created and pinned to the
187    corresponding CPU core.  For more information, please refer to
188    `man ovs-vswitchd.conf.db`
189
190         ovs-vsctl set Open_vSwitch . other_config:n-dpdk-rxqs=<integer>
191
192    The command above sets the number of rx queues of each DPDK interface. The
193    rx queues are assigned to pmd threads on the same numa node in round-robin
194    fashion.  For more information, please refer to `man ovs-vswitchd.conf.db`
195
196    Ideally for maximum throughput, the pmd thread should not be scheduled out
197    which temporarily halts its execution. The following affinitization methods
198    can help.
199
200    Lets pick core 4,6,8,10 for pmd threads to run on.  Also assume a dual 8 core
201    sandy bridge system with hyperthreading enabled where CPU1 has cores 0,...,7
202    and 16,...,23 & CPU2 cores 8,...,15 & 24,...,31.  (A different cpu
203    configuration could have different core mask requirements).
204
205    To kernel bootline add core isolation list for cores and associated hype cores
206    (e.g.  isolcpus=4,20,6,22,8,24,10,26,).  Reboot system for isolation to take
207    effect, restart everything.
208
209    Configure pmd threads on core 4,6,8,10 using 'pmd-cpu-mask':
210
211         ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=00000550
212
213    You should be able to check that pmd threads are pinned to the correct cores
214    via:
215
216         top -p `pidof ovs-vswitchd` -H -d1
217
218    Note, the pmd threads on a numa node are only created if there is at least
219    one DPDK interface from the numa node that has been added to OVS.
220
221    Note, core 0 is always reserved from non-pmd threads and should never be set
222    in the cpu mask.
223
224 DPDK Rings :
225 ------------
226
227 Following the steps above to create a bridge, you can now add dpdk rings
228 as a port to the vswitch.  OVS will expect the DPDK ring device name to
229 start with dpdkr and end with a portid.
230
231     ovs-vsctl add-port br0 dpdkr0 -- set Interface dpdkr0 type=dpdkr
232
233 DPDK rings client test application
234
235 Included in the test directory is a sample DPDK application for testing
236 the rings.  This is from the base dpdk directory and modified to work
237 with the ring naming used within ovs.
238
239 location tests/ovs_client
240
241 To run the client :
242
243     cd /usr/src/ovs/tests/
244     ovsclient -c 1 -n 4 --proc-type=secondary -- -n "port id you gave dpdkr"
245
246 In the case of the dpdkr example above the "port id you gave dpdkr" is 0.
247
248 It is essential to have --proc-type=secondary
249
250 The application simply receives an mbuf on the receive queue of the
251 ethernet ring and then places that same mbuf on the transmit ring of
252 the ethernet ring.  It is a trivial loopback application.
253
254 DPDK rings in VM (IVSHMEM shared memory communications)
255 -------------------------------------------------------
256
257 In addition to executing the client in the host, you can execute it within
258 a guest VM. To do so you will need a patched qemu.  You can download the
259 patch and getting started guide at :
260
261 https://01.org/packet-processing/downloads
262
263 A general rule of thumb for better performance is that the client
264 application should not be assigned the same dpdk core mask "-c" as
265 the vswitchd.
266
267 Restrictions:
268 -------------
269
270   - This Support is for Physical NIC. I have tested with Intel NIC only.
271   - Work with 1500 MTU, needs few changes in DPDK lib to fix this issue.
272   - Currently DPDK port does not make use any offload functionality.
273
274   ivshmem:
275   - The shared memory is currently restricted to the use of a 1GB
276     huge pages.
277   - All huge pages are shared amongst the host, clients, virtual
278     machines etc.
279
280 Bug Reporting:
281 --------------
282
283 Please report problems to bugs@openvswitch.org.
284
285 [INSTALL.userspace.md]:INSTALL.userspace.md
286 [INSTALL.md]:INSTALL.md