datapath: Add IS_ERR_OR_NULL for backward compatibility.
[cascardo/ovs.git] / INSTALL.DPDK
1                    Using Open vSwitch with DPDK
2                    ============================
3
4 Open vSwitch can use Intel(R) DPDK lib to operate entirely in
5 userspace. This file explains how to install and use Open vSwitch in
6 such a mode.
7
8 The DPDK support of Open vSwitch is considered experimental.
9 It has not been thoroughly tested.
10
11 This version of Open vSwitch should be built manually with "configure"
12 and "make".
13
14 Building and Installing:
15 ------------------------
16
17 Required DPDK 1.7.
18
19 DPDK:
20 Set dir i.g.:   export DPDK_DIR=/usr/src/dpdk-1.7.0
21 cd $DPDK_DIR
22 update config/common_linuxapp so that dpdk generate single lib file.
23 (modification also required for IVSHMEM build)
24 CONFIG_RTE_BUILD_COMBINE_LIBS=y
25
26 For default install without IVSHMEM:
27 make install T=x86_64-native-linuxapp-gcc
28 To include IVSHMEM (shared memory):
29 make install T=x86_64-ivshmem-linuxapp-gcc
30 For details refer to  http://dpdk.org/
31
32 Linux kernel:
33 Refer to intel-dpdk-getting-started-guide.pdf for understanding
34 DPDK kernel requirement.
35
36 OVS:
37 Non IVSHMEM:
38 export DPDK_BUILD=$DPDK_DIR/x86_64-native-linuxapp-gcc/
39 IVSHMEM:
40 export DPDK_BUILD=$DPDK_DIR/x86_64-ivshmem-linuxapp-gcc/
41
42 cd $(OVS_DIR)/openvswitch
43 ./boot.sh
44 ./configure --with-dpdk=$DPDK_BUILD
45 make
46
47 Refer to INSTALL.userspace for general requirements of building
48 userspace OVS.
49
50 Using the DPDK with ovs-vswitchd:
51 ---------------------------------
52
53 Setup system boot:
54    kernel bootline, add: default_hugepagesz=1GB hugepagesz=1G hugepages=1
55
56 First setup DPDK devices:
57   - insert uio.ko
58     e.g. modprobe uio
59   - insert igb_uio.ko
60     e.g. insmod $DPDK_BUILD/kmod/igb_uio.ko
61   - Bind network device to igb_uio.
62     e.g. $DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio eth1
63     Alternate binding method:
64      Find target Ethernet devices
65       lspci -nn|grep Ethernet
66      Bring Down (e.g. eth2, eth3)
67       ifconfig eth2 down
68       ifconfig eth3 down
69      Look at current devices (e.g ixgbe devices)
70       ls /sys/bus/pci/drivers/ixgbe/
71       0000:02:00.0  0000:02:00.1  bind  module  new_id  remove_id  uevent  unbind
72      Unbind target pci devices from current driver (e.g. 02:00.0 ...)
73       echo 0000:02:00.0 > /sys/bus/pci/drivers/ixgbe/unbind
74       echo 0000:02:00.1 > /sys/bus/pci/drivers/ixgbe/unbind
75      Bind to target driver (e.g. igb_uio)
76       echo 0000:02:00.0 > /sys/bus/pci/drivers/igb_uio/bind
77       echo 0000:02:00.1 > /sys/bus/pci/drivers/igb_uio/bind
78      Check binding for listed devices
79       ls /sys/bus/pci/drivers/igb_uio
80       0000:02:00.0  0000:02:00.1  bind  module  new_id  remove_id  uevent  unbind
81
82 Prepare system:
83   - mount hugetlbfs
84     e.g. mount -t hugetlbfs -o pagesize=1G none /dev/hugepages
85
86 Ref to http://www.dpdk.org/doc/quick-start for verifying DPDK setup.
87
88 Start ovsdb-server as discussed in INSTALL doc:
89   Summary e.g.:
90     First time only db creation (or clearing):
91       mkdir -p /usr/local/etc/openvswitch
92       mkdir -p /usr/local/var/run/openvswitch
93       rm /usr/local/etc/openvswitch/conf.db
94       cd $OVS_DIR
95       ./ovsdb/ovsdb-tool create /usr/local/etc/openvswitch/conf.db \
96         ./vswitchd/vswitch.ovsschema
97     start ovsdb-server
98       cd $OVS_DIR
99       ./ovsdb/ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock \
100           --remote=db:Open_vSwitch,Open_vSwitch,manager_options \
101           --private-key=db:Open_vSwitch,SSL,private_key \
102           --certificate=Open_vSwitch,SSL,certificate \
103           --bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --pidfile --detach
104     First time after db creation, initialize:
105       cd $OVS_DIR
106       ./utilities/ovs-vsctl --no-wait init
107
108 Start vswitchd:
109 DPDK configuration arguments can be passed to vswitchd via `--dpdk`
110 argument. This needs to be first argument passed to vswitchd process.
111 dpdk arg -c is ignored by ovs-dpdk, but it is a required parameter
112 for dpdk initialization.
113
114    e.g.
115    export DB_SOCK=/usr/local/var/run/openvswitch/db.sock
116    ./vswitchd/ovs-vswitchd --dpdk -c 0x1 -n 4 -- unix:$DB_SOCK --pidfile --detach
117
118 If allocated more than one GB hugepage (as for IVSHMEM), set amount and use NUMA
119 node 0 memory:
120
121    ./vswitchd/ovs-vswitchd --dpdk -c 0x1 -n 4 --socket-mem 1024,0 \
122       -- unix:$DB_SOCK --pidfile --detach
123
124 To use ovs-vswitchd with DPDK, create a bridge with datapath_type
125 "netdev" in the configuration database.  For example:
126
127     ovs-vsctl add-br br0
128     ovs-vsctl set bridge br0 datapath_type=netdev
129
130 Now you can add dpdk devices. OVS expect DPDK device name start with dpdk
131 and end with portid. vswitchd should print number of dpdk devices found.
132
133     ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
134     ovs-vsctl add-port br0 dpdk1 -- set Interface dpdk1 type=dpdk
135
136 Once first DPDK port is added to vswitchd, it creates a Polling thread and
137 polls dpdk device in continuous loop. Therefore CPU utilization
138 for that thread is always 100%.
139
140 Test flow script across NICs (assuming ovs in /usr/src/ovs):
141   Assume 1.1.1.1 on NIC port 1 (dpdk0)
142   Assume 1.1.1.2 on NIC port 2 (dpdk1)
143   Execute script:
144
145 ############################# Script:
146
147 #! /bin/sh
148 # Move to command directory
149 cd /usr/src/ovs/utilities/
150
151 # Clear current flows
152 ./ovs-ofctl del-flows br0
153
154 # Add flows between port 1 (dpdk0) to port 2 (dpdk1)
155 ./ovs-ofctl add-flow br0 in_port=1,dl_type=0x800,nw_src=1.1.1.1,\
156 nw_dst=1.1.1.2,idle_timeout=0,action=output:2
157 ./ovs-ofctl add-flow br0 in_port=2,dl_type=0x800,nw_src=1.1.1.2,\
158 nw_dst=1.1.1.1,idle_timeout=0,action=output:1
159
160 ######################################
161
162 Ideally for maximum throughput, the 100% task should not be scheduled out
163 which temporarily halts the process. The following affinitization methods will
164 help.
165
166 At this time all ovs-vswitchd tasks end up being affinitized to cpu core 0
167 but this may change. Lets pick a target core for 100% task to run on, i.e. core 7.
168 Also assume a dual 8 core sandy bridge system with hyperthreading enabled
169 where CPU1 has cores 0,...,7 and 16,...,23 & CPU2 cores 8,...,15 & 24,...,31.
170 (A different cpu configuration will have different core mask requirements).
171
172 To give better ownership of 100%, isolation maybe useful.
173 To kernel bootline add core isolation list for core 7 and associated hype core 23
174   e.g.  isolcpus=7,23
175 Reboot system for isolation to take effect, restart everything
176
177 List threads (and their pid) of ovs-vswitchd
178   top -p `pidof ovs-vswitchd` -H -d1
179
180 Look for pmd* thread which is polling dpdk devices, this will be the 100% CPU
181 bound task. Using this thread pid, affinitize to core 7 (mask 0x080),
182 example pid 1762
183
184 taskset -p 080 1762
185   pid 1762's current affinity mask: 1
186   pid 1762's new affinity mask: 80
187
188 Assume that all other ovs-vswitchd threads to be on other socket 0 cores.
189 Affinitize the rest of the ovs-vswitchd thread ids to 0x07F007F
190
191 taskset -p 0x07F007F {thread pid, e.g 1738}
192   pid 1738's current affinity mask: 1
193   pid 1738's new affinity mask: 7f007f
194 . . .
195
196 The core 23 is left idle, which allows core 7 to run at full rate.
197
198 Future changes may change the need for cpu core affinitization.
199
200 DPDK Rings :
201 ------------
202
203 Following the steps above to create a bridge, you can now add dpdk rings
204 as a port to the vswitch.  OVS will expect the DPDK ring device name to
205 start with dpdkr and end with a portid.
206
207     ovs-vsctl add-port br0 dpdkr0 -- set Interface dpdkr0 type=dpdkr
208
209 DPDK rings client test application
210
211 Included in the test directory is a sample DPDK application for testing
212 the rings.  This is from the base dpdk directory and modified to work
213 with the ring naming used within ovs.
214
215 location tests/ovs_client
216
217 To run the client :
218   cd /usr/src/ovs/tests/
219   ovsclient -c 1 -n 4 --proc-type=secondary -- -n "port id you gave dpdkr"
220
221 In the case of the dpdkr example above the "port id you gave dpdkr" is 0.
222
223 It is essential to have --proc-type=secondary
224
225 The application simply receives an mbuf on the receive queue of the
226 ethernet ring and then places that same mbuf on the transmit ring of
227 the ethernet ring.  It is a trivial loopback application.
228
229 DPDK rings in VM (IVSHMEM shared memory communications)
230 -------------------------------------------------------
231
232 In addition to executing the client in the host, you can execute it within
233 a guest VM. To do so you will need a patched qemu.  You can download the
234 patch and getting started guide at :
235
236 https://01.org/packet-processing/downloads
237
238 A general rule of thumb for better performance is that the client
239 application should not be assigned the same dpdk core mask "-c" as
240 the vswitchd.
241
242 Restrictions:
243 -------------
244
245   - This Support is for Physical NIC. I have tested with Intel NIC only.
246   - vswitchd userspace datapath does affine polling thread but it is
247     assumed that devices are on numa node 0. Therefore if device is
248     attached to non zero numa node switching performance would be
249     suboptimal.
250   - There are fixed number of polling thread and fixed number of per
251     device queues configured.
252   - Work with 1500 MTU, needs few changes in DPDK lib to fix this issue.
253   - Currently DPDK port does not make use any offload functionality.
254   ivshmem
255   - The shared memory is currently restricted to the use of a 1GB
256    huge pages.
257   - All huge pages are shared amongst the host, clients, virtual
258    machines etc.
259
260 Bug Reporting:
261 --------------