datapath-windows: Add port friendly name to OVS_VPORT_ENTRY
[cascardo/ovs.git] / INSTALL.DPDK
1                    Using Open vSwitch with DPDK
2                    ============================
3
4 Open vSwitch can use Intel(R) DPDK lib to operate entirely in
5 userspace. This file explains how to install and use Open vSwitch in
6 such a mode.
7
8 The DPDK support of Open vSwitch is considered experimental.
9 It has not been thoroughly tested.
10
11 This version of Open vSwitch should be built manually with "configure"
12 and "make".
13
14 Building and Installing:
15 ------------------------
16
17 Required DPDK 1.7.
18
19 DPDK:
20 Set dir i.g.:   export DPDK_DIR=/usr/src/dpdk-1.7.0
21 cd $DPDK_DIR
22 update config/common_linuxapp so that dpdk generate single lib file.
23 (modification also required for IVSHMEM build)
24 CONFIG_RTE_BUILD_COMBINE_LIBS=y
25
26 For default install without IVSHMEM:
27 make install T=x86_64-native-linuxapp-gcc
28 To include IVSHMEM (shared memory):
29 make install T=x86_64-ivshmem-linuxapp-gcc
30 For details refer to  http://dpdk.org/
31
32 Linux kernel:
33 Refer to intel-dpdk-getting-started-guide.pdf for understanding
34 DPDK kernel requirement.
35
36 OVS:
37 Non IVSHMEM:
38 export DPDK_BUILD=$DPDK_DIR/x86_64-native-linuxapp-gcc/
39 IVSHMEM:
40 export DPDK_BUILD=$DPDK_DIR/x86_64-ivshmem-linuxapp-gcc/
41
42 cd $(OVS_DIR)/openvswitch
43 ./boot.sh
44 ./configure --with-dpdk=$DPDK_BUILD
45 make
46
47 Refer to INSTALL.userspace for general requirements of building
48 userspace OVS.
49
50 Using the DPDK with ovs-vswitchd:
51 ---------------------------------
52
53 Setup system boot:
54    kernel bootline, add: default_hugepagesz=1GB hugepagesz=1G hugepages=1
55
56 First setup DPDK devices:
57   - insert uio.ko
58     e.g. modprobe uio
59   - insert igb_uio.ko
60     e.g. insmod $DPDK_BUILD/kmod/igb_uio.ko
61   - Bind network device to igb_uio.
62     e.g. $DPDK_DIR/tools/dpdk_nic_bind.py --bind=igb_uio eth1
63     Alternate binding method:
64      Find target Ethernet devices
65       lspci -nn|grep Ethernet
66      Bring Down (e.g. eth2, eth3)
67       ifconfig eth2 down
68       ifconfig eth3 down
69      Look at current devices (e.g ixgbe devices)
70       ls /sys/bus/pci/drivers/ixgbe/
71       0000:02:00.0  0000:02:00.1  bind  module  new_id  remove_id  uevent  unbind
72      Unbind target pci devices from current driver (e.g. 02:00.0 ...)
73       echo 0000:02:00.0 > /sys/bus/pci/drivers/ixgbe/unbind
74       echo 0000:02:00.1 > /sys/bus/pci/drivers/ixgbe/unbind
75      Bind to target driver (e.g. igb_uio)
76       echo 0000:02:00.0 > /sys/bus/pci/drivers/igb_uio/bind
77       echo 0000:02:00.1 > /sys/bus/pci/drivers/igb_uio/bind
78      Check binding for listed devices
79       ls /sys/bus/pci/drivers/igb_uio
80       0000:02:00.0  0000:02:00.1  bind  module  new_id  remove_id  uevent  unbind
81
82 Prepare system:
83   - mount hugetlbfs
84     e.g. mount -t hugetlbfs -o pagesize=1G none /dev/hugepages
85
86 Ref to http://www.dpdk.org/doc/quick-start for verifying DPDK setup.
87
88 Start ovsdb-server as discussed in INSTALL doc:
89   Summary e.g.:
90     First time only db creation (or clearing):
91       mkdir -p /usr/local/etc/openvswitch
92       mkdir -p /usr/local/var/run/openvswitch
93       rm /usr/local/etc/openvswitch/conf.db
94       cd $OVS_DIR
95       ./ovsdb/ovsdb-tool create /usr/local/etc/openvswitch/conf.db \
96         ./vswitchd/vswitch.ovsschema
97     start ovsdb-server
98       cd $OVS_DIR
99       ./ovsdb/ovsdb-server --remote=punix:/usr/local/var/run/openvswitch/db.sock \
100           --remote=db:Open_vSwitch,Open_vSwitch,manager_options \
101           --private-key=db:Open_vSwitch,SSL,private_key \
102           --certificate=Open_vSwitch,SSL,certificate \
103           --bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --pidfile --detach
104     First time after db creation, initialize:
105       cd $OVS_DIR
106       ./utilities/ovs-vsctl --no-wait init
107
108 Start vswitchd:
109 DPDK configuration arguments can be passed to vswitchd via `--dpdk`
110 argument. This needs to be first argument passed to vswitchd process.
111 dpdk arg -c is ignored by ovs-dpdk, but it is a required parameter
112 for dpdk initialization.
113
114    e.g.
115    export DB_SOCK=/usr/local/var/run/openvswitch/db.sock
116    ./vswitchd/ovs-vswitchd --dpdk -c 0x1 -n 4 -- unix:$DB_SOCK --pidfile --detach
117
118 If allocated more than one GB hugepage (as for IVSHMEM), set amount and use NUMA
119 node 0 memory:
120
121    ./vswitchd/ovs-vswitchd --dpdk -c 0x1 -n 4 --socket-mem 1024,0 \
122       -- unix:$DB_SOCK --pidfile --detach
123
124 To use ovs-vswitchd with DPDK, create a bridge with datapath_type
125 "netdev" in the configuration database.  For example:
126
127     ovs-vsctl add-br br0
128     ovs-vsctl set bridge br0 datapath_type=netdev
129
130 Now you can add dpdk devices. OVS expect DPDK device name start with dpdk
131 and end with portid. vswitchd should print number of dpdk devices found.
132
133     ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk
134     ovs-vsctl add-port br0 dpdk1 -- set Interface dpdk1 type=dpdk
135
136 Once first DPDK port is added to vswitchd, it creates a Polling thread and
137 polls dpdk device in continuous loop. Therefore CPU utilization
138 for that thread is always 100%.
139
140 Test flow script across NICs (assuming ovs in /usr/src/ovs):
141   Assume 1.1.1.1 on NIC port 1 (dpdk0)
142   Assume 1.1.1.2 on NIC port 2 (dpdk1)
143   Execute script:
144
145 ############################# Script:
146
147 #! /bin/sh
148 # Move to command directory
149 cd /usr/src/ovs/utilities/
150
151 # Clear current flows
152 ./ovs-ofctl del-flows br0
153
154 # Add flows between port 1 (dpdk0) to port 2 (dpdk1)
155 ./ovs-ofctl add-flow br0 in_port=1,dl_type=0x800,nw_src=1.1.1.1,\
156 nw_dst=1.1.1.2,idle_timeout=0,action=output:2
157 ./ovs-ofctl add-flow br0 in_port=2,dl_type=0x800,nw_src=1.1.1.2,\
158 nw_dst=1.1.1.1,idle_timeout=0,action=output:1
159
160 ######################################
161
162 With pmd multi-threading support, OVS creates one pmd thread for each
163 numa node as default.  The pmd thread handles the I/O of all DPDK
164 interfaces on the same numa node.  The following two commands can be used
165 to configure the multi-threading behavior.
166
167     ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=<hex string>
168
169 The command above asks for a CPU mask for setting the affinity of pmd threads.
170 A set bit in the mask means a pmd thread is created and pinned to the
171 corresponding CPU core.  For more information, please refer to
172 `man ovs-vswitchd.conf.db`
173
174     ovs-vsctl set Open_vSwitch . other_config:n-dpdk-rxqs=<integer>
175
176 The command above sets the number of rx queues of each DPDK interface.  The
177 rx queues are assigned to pmd threads on the same numa node in round-robin
178 fashion.  For more information, please refer to `man ovs-vswitchd.conf.db`
179
180 Ideally for maximum throughput, the pmd thread should not be scheduled out
181 which temporarily halts its execution. The following affinitization methods
182 can help.
183
184 Lets pick core 4,6,8,10 for pmd threads to run on.  Also assume a dual 8 core
185 sandy bridge system with hyperthreading enabled where CPU1 has cores 0,...,7
186 and 16,...,23 & CPU2 cores 8,...,15 & 24,...,31.  (A different cpu
187 configuration could have different core mask requirements).
188
189 To kernel bootline add core isolation list for cores and associated hype cores
190 (e.g.  isolcpus=4,20,6,22,8,24,10,26,).  Reboot system for isolation to take
191 effect, restart everything.
192
193 Configure pmd threads on core 4,6,8,10 using 'pmd-cpu-mask':
194
195     ovs-vsctl set Open_vSwitch . other_config:pmd-cpu-mask=00000550
196
197 You should be able to check that pmd threads are pinned to the correct cores
198 via:
199
200     top -p `pidof ovs-vswitchd` -H -d1
201
202 Note, the pmd threads on a numa node are only created if there is at least
203 one DPDK interface from the numa node that has been added to OVS.
204
205 Note, core 0 is always reserved from non-pmd threads and should never be set
206 in the cpu mask.
207
208 DPDK Rings :
209 ------------
210
211 Following the steps above to create a bridge, you can now add dpdk rings
212 as a port to the vswitch.  OVS will expect the DPDK ring device name to
213 start with dpdkr and end with a portid.
214
215     ovs-vsctl add-port br0 dpdkr0 -- set Interface dpdkr0 type=dpdkr
216
217 DPDK rings client test application
218
219 Included in the test directory is a sample DPDK application for testing
220 the rings.  This is from the base dpdk directory and modified to work
221 with the ring naming used within ovs.
222
223 location tests/ovs_client
224
225 To run the client :
226   cd /usr/src/ovs/tests/
227   ovsclient -c 1 -n 4 --proc-type=secondary -- -n "port id you gave dpdkr"
228
229 In the case of the dpdkr example above the "port id you gave dpdkr" is 0.
230
231 It is essential to have --proc-type=secondary
232
233 The application simply receives an mbuf on the receive queue of the
234 ethernet ring and then places that same mbuf on the transmit ring of
235 the ethernet ring.  It is a trivial loopback application.
236
237 DPDK rings in VM (IVSHMEM shared memory communications)
238 -------------------------------------------------------
239
240 In addition to executing the client in the host, you can execute it within
241 a guest VM. To do so you will need a patched qemu.  You can download the
242 patch and getting started guide at :
243
244 https://01.org/packet-processing/downloads
245
246 A general rule of thumb for better performance is that the client
247 application should not be assigned the same dpdk core mask "-c" as
248 the vswitchd.
249
250 Restrictions:
251 -------------
252
253   - This Support is for Physical NIC. I have tested with Intel NIC only.
254   - Work with 1500 MTU, needs few changes in DPDK lib to fix this issue.
255   - Currently DPDK port does not make use any offload functionality.
256   ivshmem
257   - The shared memory is currently restricted to the use of a 1GB
258    huge pages.
259   - All huge pages are shared amongst the host, clients, virtual
260    machines etc.
261
262 Bug Reporting:
263 --------------