4 .  IP "\\$1"
5 ..
6 .TH ovs\-test 1 "@VERSION@" "Open vSwitch" "Open vSwitch Manual"
7 .
8 .SH NAME
9 \fBovs\-test\fR \- check Linux drivers for performance, vlan and L3 tunneling
10 problems
11 .
12 .SH SYNOPSIS
13 \fBovs\-test\fR \fB\-s\fR \fIport\fR
14 .PP
15 \fBovs\-test\fR \fB\-c\fR \fIserver1\fR \fIserver2\fR
16 [\fB\-b\fR \fItargetbandwidth\fR] [\fB\-i\fR \fItestinterval\fR]
17 [\fB\-d\fR]
18 [\fB\-l\fR \fIvlantag\fR]
19 [\fB\-t\fR \fItunnelmodes\fR]
20 .so lib/common-syn.man
21 .
22 .SH DESCRIPTION
23 The \fBovs\-test\fR program may be used to check for problems sending
24 802.1Q or GRE traffic that Open vSwitch may uncover. These problems,
25 for example, can occur when Open vSwitch is used to send 802.1Q traffic
26 through physical interfaces running certain drivers of certain Linux kernel
27 versions. To run a test, configure IP addresses on \fIserver1\fR and
28 \fIserver2\fR for interfaces you intended to test. These interfaces could
29 also be already configured OVS bridges that have a physical interface attached
30 to them. Then, on one of the nodes, run \fBovs\-test\fR in server mode and on
31 the other node run it in client mode. The client will connect to
32 \fBovs\-test\fR server and schedule tests between both of them. The
33 \fBovs\-test\fR client will perform UDP and TCP tests.
34 .PP
35 UDP tests can report packet loss and achieved bandwidth for various
36 datagram sizes. By default target bandwidth for UDP tests is 1Mbit/s.
37 .PP
38 TCP tests report only achieved bandwidth, because kernel TCP stack
39 takes care of flow control and packet loss. TCP tests are essential to detect
40 potential TSO related issues.
41 .PP
42 To determine whether Open vSwitch is encountering any problems,
43 the user must compare packet loss and achieved bandwidth in a setup where
44 traffic is being directly sent and in one where it is not. If in the
45 802.1Q or L3 tunneled tests both \fBovs\-test\fR processes are unable to
46 communicate or the achieved bandwidth is much lower compared to direct setup,
47 then, most likely, Open vSwitch has encountered a pre-existing kernel or
48 driver bug.
49 .PP
50 Some examples of the types of problems that may be encountered are:
51 .so utilities/ovs-vlan-bugs.man
52 .
53 .SS "Client Mode"
54 An \fBovs\-test\fR client will connect to two \fBovs\-test\fR servers and
55 will ask them to exchange test traffic. It is also possible to spawn an
56 \fBovs\-test\fR server automatically from the client.
57 .
58 .SS "Server Mode"
59 To conduct tests, two \fBovs\-test\fR servers must be running on two different
60 hosts where the client can connect. The actual test traffic is exchanged only
61 between both \fBovs\-test\fR servers. It is recommended that both servers have
62 their IP addresses in the same subnet, otherwise one would have to make sure
63 that routing is set up correctly.
64 .
65 .SH OPTIONS
66 .
67 .IP "\fB\-s \fIport\fR"
68 .IQ "\fB\-\-server\fR \fIport\fR"
69 Run in server mode and wait for the client to establish XML RPC Control
70 Connection on this TCP \fIport\fR. It is recommended to have \fBethtool\fR(8)
71 installed on the server so that it could retrieve information about the NIC
72 driver.
73 .
74 .IP "\fB\-c \fIserver1\fR \fIserver2\fR"
75 .IQ "\fB\-\-client \fIserver1\fR \fIserver2\fR"
76 Run in client mode and schedule tests between \fIserver1\fR and \fIserver2\fR,
77 where each \fIserver\fR must be given in the following format -
78 \fIOuterIP[:OuterPort],InnerIP[/Mask][:InnerPort]\fR. The \fIOuterIP\fR must
79 be already assigned to the physical interface which is going to be tested.
80 This is the IP address where client will try to establish XML RPC connection.
81 If \fIOuterIP\fR is 127.0.0.1 then client will automatically spawn a local
82 instance of \fBovs\-test\fR server. \fIOuterPort\fR is TCP port where server
83 is listening for incoming XML/RPC control connections to schedule tests (by
84 default it is 15531). The \fBovs\-test\fR will automatically assign
85 \fIInnerIP[/Mask]\fR to the interfaces that will be created on the fly for
86 testing purposes. It is important that \fIInnerIP[/Mask]\fR does not interfere
87 with already existing IP addresses on both \fBovs\-test\fR servers and client.
88 \fIInnerPort\fR is port which will be used by server to listen for test
89 traffic that will be encapsulated (by default it is 15532).
90 .
91 .IP "\fB\-b \fItargetbandwidth\fR"
92 .IQ "\fB\-\-bandwidth\fR \fItargetbandwidth\fR"
93 Target bandwidth for UDP tests. The \fItargetbandwidth\fR must be given in
94 bits per second. It is possible to use postfix M or K to alter the target
95 bandwidth magnitude.
96 .
97 .IP "\fB\-i \fItestinterval\fR"
98 .IQ "\fB\-\-interval\fR \fItestinterval\fR"
99 How long each test should run. By default 5 seconds.
100 .
101 .so lib/common.man
102 .
103 .SH "Test Modes"
104 The following test modes are supported by \fBovs\-test\fR. It is possible
105 to combine multiple of them in a single \fBovs\-test\fR invocation.
106 .
107 .IP "\fB\-d \fR"
108 .IQ "\fB\-\-direct\fR"
109 Perform direct tests between both \fIOuterIP\fR addresses. These tests could
110 be used as a reference to compare 802.1Q or L3 tunneling test results.
111 .
112 .IP "\fB\-l \fIvlantag\fR"
113 .IQ "\fB\-\-vlan\-tag\fR \fIvlantag\fR"
114 Perform 802.1Q tests between both servers. These tests will create a temporary
115 OVS bridge, if necessary, and attach a VLAN tagged port to it for testing
116 purposes.
117 .
118 .IP "\fB\-t \fItunnelmodes\fR"
119 .IQ "\fB\-\-tunnel\-modes\fR \fItunnelmodes\fR"
120 Perform L3 tunneling tests. The given argument is a comma separated string
121 that specifies all the L3 tunnel modes that should be tested (e.g. gre). The L3
122 tunnels are terminated on interface that has the \fIOuterIP\fR address
123 assigned.
124 .
125 .SH EXAMPLES
126 .PP
127 On host 1.2.3.4 start \fBovs\-test\fR in server mode:
128 .IP
129 .B ovs\-test \-s 15531
130 .
131 .PP
132 On host 1.2.3.5 start \fBovs\-test\fR in client mode and do direct, VLAN and
133 GRE tests between both nodes:
134 .IP
135 .B ovs\-test \-c 127.0.0.1,1.1.1.1/30 1.2.3.4,1.1.1.2/30 -d -l 123 -t gre
136 .
137 .SH SEE ALSO
138 .
139 .BR ovs\-vswitchd (8),
140 .BR ovs\-ofctl (8),
141 .BR ovs\-vsctl (8),
142 .BR ovs\-vlan\-test (8),