21fb6db89f34d93977dd8140769dbdd7ff2b0f11
[cascardo/ovs.git] / vtep / vtep-ctl.8.in
1 .\" -*- nroff -*-
2 .de IQ
3 .  br
4 .  ns
5 .  IP "\\$1"
6 ..
7 .de ST
8 .  PP
9 .  RS -0.15in
10 .  I "\\$1"
11 .  RE
12 ..
13 .TH vtep\-ctl 8 "March 2013" "Open vSwitch" "Open vSwitch Manual"
14 .\" This program's name:
15 .ds PN vtep\-ctl
16 .
17 .SH NAME
18 vtep\-ctl \- utility for querying and configuring a VTEP database
19 .
20 .SH SYNOPSIS
21 \fBvtep\-ctl\fR [\fIoptions\fR] \fB\-\-\fR [\fIoptions\fR] \fIcommand
22 \fR[\fIargs\fR] [\fB\-\-\fR [\fIoptions\fR] \fIcommand \fR[\fIargs\fR]]...
23 .
24 .SH DESCRIPTION
25 The \fBvtep\-ctl\fR program configures a VTEP database.
26 See \fBvtep\fR(5) for comprehensive documentation of
27 the database schema.
28 .PP
29 \fBvtep\-ctl\fR connects to an \fBovsdb\-server\fR process that
30 maintains a VTEP configuration database.  Using this connection, it
31 queries and possibly applies changes to the database, depending on the
32 supplied commands.
33 .PP
34 \fBvtep\-ctl\fR can perform any number of commands in a single run,
35 implemented as a single atomic transaction against the database.
36 .PP
37 The \fBvtep\-ctl\fR command line begins with global options (see
38 \fBOPTIONS\fR below for details).  The global options are followed by
39 one or more commands.  Each command should begin with \fB\-\-\fR by
40 itself as a command-line argument, to separate it from the following
41 commands.  (The \fB\-\-\fR before the first command is optional.)  The
42 command itself starts with command-specific options, if any, followed by
43 the command name and any arguments.  See \fBEXAMPLES\fR below for syntax
44 examples.
45 .
46 .SH OPTIONS
47 .
48 The following options affect the behavior \fBvtep\-ctl\fR as a whole.
49 Some individual commands also accept their own options, which are
50 given just before the command name.  If the first command on the
51 command line has options, then those options must be separated from
52 the global options by \fB\-\-\fR.
53 .
54 .IP "\fB\-\-db=\fIserver\fR"
55 Sets \fIserver\fR as the database server that \fBvtep\-ctl\fR
56 contacts to query or modify configuration.  The default is
57 \fBunix:@RUNDIR@/db.sock\fR.  \fIserver\fR must take one of the
58 following forms:
59 .RS
60 .so ovsdb/remote-active.man
61 .so ovsdb/remote-passive.man
62 .RE
63 .
64 .IP "\fB\-\-no\-syslog\fR"
65 By default, \fBvtep\-ctl\fR logs its arguments and the details of any
66 changes that it makes to the system log.  This option disables this
67 logging.
68 .IP
69 This option is equivalent to \fB\-\-verbose=vtep_ctl:syslog:warn\fR.
70 .
71 .IP "\fB\-\-oneline\fR"
72 Modifies the output format so that the output for each command is printed
73 on a single line.  New-line characters that would otherwise separate
74 lines are printed as \fB\\n\fR, and any instances of \fB\\\fR that
75 would otherwise appear in the output are doubled.
76 Prints a blank line for each command that has no output.
77 This option does not affect the formatting of output from the
78 \fBlist\fR or \fBfind\fR commands; see \fBTable Formatting Options\fR
79 below.
80 .
81 .IP "\fB\-\-dry\-run\fR"
82 Prevents \fBvtep\-ctl\fR from actually modifying the database.
83 .
84 .IP "\fB\-t \fIsecs\fR"
85 .IQ "\fB\-\-timeout=\fIsecs\fR"
86 By default, or with a \fIsecs\fR of \fB0\fR, \fBvtep\-ctl\fR waits
87 forever for a response from the database.  This option limits runtime
88 to approximately \fIsecs\fR seconds.  If the timeout expires,
89 \fBvtep\-ctl\fR will exit with a \fBSIGALRM\fR signal.  (A timeout
90 would normally happen only if the database cannot be contacted, or if
91 the system is overloaded.)
92 .
93 .SS "Table Formatting Options"
94 These options control the format of output from the \fBlist\fR and
95 \fBfind\fR commands.
96 .so lib/table.man
97 .
98 .SS "Public Key Infrastructure Options"
99 .so lib/ssl.man
100 .so lib/ssl-bootstrap.man
101 .so lib/ssl-peer-ca-cert.man
102 .so lib/vlog.man
103 .so lib/common.man
104 .
105 .SH COMMANDS
106 The commands implemented by \fBvtep\-ctl\fR are described in the
107 sections below.
108 .
109 .SS "Physical Switch Commands"
110 These commands examine and manipulate physical switches.
111 .
112 .IP "[\fB\-\-may\-exist\fR] \fBadd\-ps \fIpswitch\fR"
113 Creates a new physical switch named \fIpswitch\fR.  Initially the switch
114 will have no ports.
115 .IP
116 Without \fB\-\-may\-exist\fR, attempting to create a switch that
117 exists is an error.  With \fB\-\-may\-exist\fR, this command does
118 nothing if \fIpswitch\fR already exists.
119 .
120 .IP "[\fB\-\-if\-exists\fR] \fBdel\-ps \fIpswitch\fR"
121 Deletes \fIpswitch\fR and all of its ports.
122 .IP
123 Without \fB\-\-if\-exists\fR, attempting to delete a switch that does
124 not exist is an error.  With \fB\-\-if\-exists\fR, attempting to
125 delete a switch that does not exist has no effect.
126 .
127 .IP "\fBlist\-ps\fR"
128 Lists all existing physical switches on standard output, one per line.
129 .
130 .IP "\fBps\-exists \fIpswitch\fR"
131 Tests whether \fIpswitch\fR exists.  If so, \fBvtep\-ctl\fR exits
132 successfully with exit code 0.  If not, \fBvtep\-ctl\fR exits
133 unsuccessfully with exit code 2.
134 .
135 .SS "Port Commands"
136 .
137 These commands examine and manipulate VTEP physical ports.
138 .
139 .IP "\fBlist\-ports \fIpswitch\fR"
140 Lists all of the ports within \fIpswitch\fR on standard output, one per
141 line.
142 .
143 .IP "[\fB\-\-may\-exist\fR] \fBadd\-port \fIpswitch port\fR"
144 Creates on \fIpswitch\fR a new port named \fIport\fR from the network
145 device of the same name.
146 .IP
147 Without \fB\-\-may\-exist\fR, attempting to create a port that exists
148 is an error.  With \fB\-\-may\-exist\fR, this command does nothing if
149 \fIport\fR already exists on \fIpswitch\fR.
150 .
151 .IP "[\fB\-\-if\-exists\fR] \fBdel\-port \fR[\fIpswitch\fR] \fIport\fR"
152 Deletes \fIport\fR.  If \fIpswitch\fR is omitted, \fIport\fR is removed
153 from whatever switch contains it; if \fIpswitch\fR is specified, it
154 must be the switch that contains \fIport\fR.
155 .IP
156 Without \fB\-\-if\-exists\fR, attempting to delete a port that does
157 not exist is an error.  With \fB\-\-if\-exists\fR, attempting to
158 delete a port that does not exist has no effect.
159 .
160 .SS "Logical Switch Commands"
161 These commands examine and manipulate logical switches.
162 .
163 .IP "[\fB\-\-may\-exist\fR] \fBadd\-ls \fIlswitch\fR"
164 Creates a new logical switch named \fIlswitch\fR.  Initially the switch
165 will have no locator bindings.
166 .IP
167 Without \fB\-\-may\-exist\fR, attempting to create a switch that
168 exists is an error.  With \fB\-\-may\-exist\fR, this command does
169 nothing if \fIlswitch\fR already exists.
170 .
171 .IP "[\fB\-\-if\-exists\fR] \fBdel\-ls \fIlswitch\fR"
172 Deletes \fIlswitch\fR.
173 .IP
174 Without \fB\-\-if\-exists\fR, attempting to delete a switch that does
175 not exist is an error.  With \fB\-\-if\-exists\fR, attempting to
176 delete a switch that does not exist has no effect.
177 .
178 .IP "\fBlist\-ls\fR"
179 Lists all existing logical switches on standard output, one per line.
180 .
181 .IP "\fBls\-exists \fIlswitch\fR"
182 Tests whether \fIlswitch\fR exists.  If so, \fBvtep\-ctl\fR exits
183 successfully with exit code 0.  If not, \fBvtep\-ctl\fR exits
184 unsuccessfully with exit code 2.
185 .
186 .IP "\fBbind\-ls \fIpswitch port vlan lswitch\fR"
187 Bind logical switch \fIlswitch\fR to the \fIport\fR/\fIvlan\fR
188 combination on the physical switch \fIpswitch\fR.
189 .
190 .IP "\fBunbind\-ls \fIpswitch port vlan\fR"
191 Remove the logical switch binding from the \fIport\fR/\fIvlan\fR
192 combination on the physical switch \fIpswitch\fR.
193 .
194 .IP "\fBlist\-bindings \fIpswitch port\fR"
195 List the logical switch bindings for \fIport\fR on the physical switch
196 \fIpswitch\fR.
197 .
198 .SS "Local MAC Binding Commands"
199 These commands examine and manipulate local MAC bindings for the logical
200 switch.  The local maps are written by the VTEP to refer to MACs it has
201 learned on its physical ports.
202 .
203 .IP "\fBadd\-ucast\-local \fIlswitch mac\fR [\fIencap\fR] \fIip\fR"
204 Map the unicast Ethernet address \fImac\fR to the physical location
205 \fIip\fR using encapsulation \fIencap\fR on \fIlswitch\fR.  If
206 \fIencap\fR is not specified, the default is "vxlan_over_ipv4".  The
207 local mappings are used by the VTEP to refer to MACs learned on its
208 physical ports.
209 .
210 .IP "\fBdel\-ucast\-local \fIlswitch mac\fR"
211 Remove the local unicast Ethernet address \fImac\fR map from
212 \fIlswitch\fR.  The local mappings are used by the VTEP to refer to MACs
213 learned on its physical ports.
214 .
215 .IP "\fBadd\-mcast\-local \fIlswitch mac\fR [\fIencap\fR] \fIip\fR"
216 Add physical location \fIip\fR using encapsulation \fIencap\fR to the
217 local mac binding table for multicast Ethernet address \fImac\fR on
218 \fIlswitch\fR.  If \fIencap\fR is not specified, the default is
219 "vxlan_over_ipv4".  The local mappings are used by the VTEP to refer to
220 MACs learned on its physical ports.
221 .
222 .IP "\fBdel\-mcast\-local \fIlswitch mac\fR [\fIencap\fR] \fIip\fR"
223 Remove physical location \fIip\fR using encapsulation \fIencap\fR from
224 the local mac binding table for multicast Ethernet address \fImac\fR on
225 \fIlswitch\fR.  If \fIencap\fR is not specified, the default is
226 "vxlan_over_ipv4".  The local mappings are used by the VTEP to refer to
227 MACs learned on its physical ports.
228 .
229 .IP "\fBclear\-local\-macs \fIlswitch\fR"
230 Clear the local MAC bindings for \fIlswitch\fR.
231 .
232 .IP "\fBlist\-local\-macs \fIlswitch\fR"
233 List the local MAC bindings for \fIlswitch\fR, one per line.
234 .
235 .SS "Remote MAC Binding Commands"
236 These commands examine and manipulate local and remote MAC bindings for
237 the logical switch.  The remote maps are written by the network
238 virtualization controller to refer to MACs that it has learned.
239 .
240 .IP "\fBadd\-ucast\-remote \fIlswitch mac\fR [\fIencap\fR] \fIip\fR"
241 Map the unicast Ethernet address \fImac\fR to the physical location
242 \fIip\fR using encapsulation \fIencap\fR on \fIlswitch\fR.  If
243 \fIencap\fR is not specified, the default is "vxlan_over_ipv4".  The
244 remote mappings are used by the network virtualization platform to refer
245 to MACs that it has learned.
246 .
247 .IP "\fBdel\-ucast\-remote \fIlswitch mac\fR"
248 Remove the remote unicast Ethernet address \fImac\fR map from
249 \fIlswitch\fR.  The remote mappings are used by the network
250 virtualization platform to refer to MACs that it has learned.
251 .
252 .IP "\fBadd\-mcast\-remote \fIlswitch mac\fR [\fIencap\fR] \fIip\fR"
253 Add physical location \fIip\fR using encapsulation \fIencap\fR to the
254 remote mac binding table for multicast Ethernet address \fImac\fR on
255 \fIlswitch\fR.  If \fIencap\fR is not specified, the default is
256 "vxlan_over_ipv4".  The remote mappings are used by the network
257 virtualization platform to refer to MACs that it has learned.
258 .
259 .IP "\fBdel\-mcast\-remote \fIlswitch mac\fR [\fIencap\fR] \fIip\fR"
260 Remove physical location \fIip\fR using encapsulation \fIencap\fR from
261 the remote mac binding table for multicast Ethernet address \fImac\fR on
262 \fIlswitch\fR.  If \fIencap\fR is not specified, the default is
263 "vxlan_over_ipv4".  The remote mappings are used by the network
264 virtualization platform to refer to MACs that it has learned.
265 .
266 .IP "\fBclear\-remote\-macs \fIlswitch\fR"
267 Clear the remote MAC bindings for \fIlswitch\fR.
268 .
269 .IP "\fBlist\-remote\-macs \fIlswitch\fR"
270 List the remote MAC bindings for \fIlswitch\fR, one per line.
271 .
272 .SS "Manager Connectivity"
273 .
274 These commands manipulate the \fBmanagers\fR column in the \fBGlobal\fR
275 table and rows in the \fBManagers\fR table.  When \fBovsdb\-server\fR is
276 configured to use the \fBmanagers\fR column for OVSDB connections (as
277 described in \fBINSTALL.Linux\fR and in the startup scripts provided
278 with Open vSwitch), this allows the administrator to use \fBvtep\-ctl\fR
279 to configure database connections.
280 .
281 .IP "\fBget\-manager\fR"
282 Prints the configured manager(s).
283 .
284 .IP "\fBdel\-manager\fR"
285 Deletes the configured manager(s).
286 .
287 .IP "\fBset\-manager\fR \fItarget\fR\&..."
288 Sets the configured manager target or targets.  Each \fItarget\fR may
289 use any of the following forms:
290 .
291 .RS
292 .so ovsdb/remote-active.man
293 .so ovsdb/remote-passive.man
294 .RE
295 .
296 .SS "Database Commands"
297 .
298 These commands query and modify the contents of \fBovsdb\fR tables.
299 They are a slight abstraction of the \fBovsdb\fR interface and as such
300 they operate at a lower level than other \fBvtep\-ctl\fR commands.
301 .PP
302 .ST "Identifying Tables, Records, and Columns"
303 .PP
304 Each of these commands has a \fItable\fR parameter to identify a table
305 within the database.  Many of them also take a \fIrecord\fR parameter
306 that identifies a particular record within a table.  The \fIrecord\fR
307 parameter may be the UUID for a record, and many tables offer
308 additional ways to identify records.  Some commands also take
309 \fIcolumn\fR parameters that identify a particular field within the
310 records in a table.
311 .PP
312 The following tables are currently defined:
313 .IP "\fBGlobal\fR"
314 Top-level configuration for a hardware VTEP.  This table contains
315 exactly one record, identified by specifying \fB.\fR as the record name.
316 .IP "\fBManager\fR"
317 Configuration for an OVSDB connection.  Records may be identified
318 by target (e.g. \fBtcp:1.2.3.4\fR).
319 .IP "\fBPhysical_Switch\fR"
320 A physical switch that implements a VTEP.  Records may be identified by
321 physical switch name.
322 .IP "\fBPhysical_Port\fR"
323 A port within a physical switch.
324 .IP "\fBLogical_Binding_Stats\fR"
325 Reports statistics for the logical switch with which a VLAN on a
326 physical port is associated.
327 .IP "\fBLogical_Switch\fR"
328 A logical Ethernet switch.  Records may be identified by logical switch
329 name.
330 .IP "\fBUcast_Macs_Local\fR"
331 Mapping of locally discovered unicast MAC addresses to tunnels.
332 .IP "\fBUcast_Macs_Remote\fR"
333 Mapping of remotely programmed unicast MAC addresses to tunnels.
334 .IP "\fBMcast_Macs_Local\fR"
335 Mapping of locally discovered multicast MAC addresses to tunnels.
336 .IP "\fBMcast_Macs_Remote\fR"
337 Mapping of remotely programmed multicast MAC addresses to tunnels.
338 .IP "\fBPhysical_Locator_Set\fR"
339 A set of one or more physical locators.
340 .IP "\fBPhysical_Locator\fR"
341 Identifies an endpoint to which logical switch traffic may be
342 encapsulated and forwarded.  Records may be identified by physical
343 locator name.
344 .PP
345 Record names must be specified in full and with correct
346 capitalization.  Names of tables and columns are not case-sensitive,
347 and \fB\-\-\fR and \fB_\fR are treated interchangeably.  Unique
348 abbreviations are acceptable, e.g. \fBman\fR or \fBm\fR is sufficient
349 to identify the \fBManager\fR table.
350 .
351 .so lib/db-ctl-base.man
352 .PP
353 .SH "EXIT STATUS"
354 .IP "0"
355 Successful program execution.
356 .IP "1"
357 Usage, syntax, or configuration file error.
358 .IP "2"
359 The \fIswitch\fR argument to \fBps\-exists\fR specified the name of a
360 physical switch that does not exist.
361 .SH "SEE ALSO"
362 .
363 .BR ovsdb\-server (1),
364 .BR vtep (5).